EUTEC™ FS - Installation case study 14
(14) Cleaning of motor parts (soldering process)
Aim of EUTEC installation | Removal of water contaminant entering hydrocarbon-based cleaning fluid during recycling by distillation |
---|---|
Expected benefits of EUTEC installation | Improve quality of recycled hydrocarbon-based cleaning fluid |
Cleaning target | Precision metal parts |
Separation target fluid | Water (moisture) |
Type of cleaner being used | Hydrocarbon-based cleaner |
Operating temperature of cleaner | 35℃ |
Model of oil-water separator used (process flow rate) | TK-15 (5L/min) |
Installation flow diagram
*Click here for more examples of cleaning-related installation flows.