EUTEC™ FS/MF - Installation case study 20
(20) Application in motor manufacturing 1 (pressing process)
Aim of EUTEC installation | Removal of press oil during the cleaning of motor parts |
---|---|
Expected benefits of EUTEC installation | Improve quality of cleaning and prolong service life of cleaning fluid and rinse water |
Cleaning target | Motor parts (motor housings) |
Type of dirt/contaminant | Press oil, dust |
Type of cleaner being used | Alkaline degreaser |
Operating temperature of cleaner | 60℃ |
Model of oil-water separator used (process flow rate) | TH-15 (15L/min) |
Pressing process
Process | Filter usage point | Filter | Purpose of filter installation | Asahi Kasei filter series used |
---|---|---|---|---|
Pressing | Cleaning with alkaline cleaner | MF1 | Removal of foreign objects | KNP, AMWPP |
MF2 | Removal of foreign objects, pre-filtering |
KNP, AMWPP | ||
TH1 | Separation of oil | TH oil-water separator | ||
Rinsing with water | MF3 | Removal of foreign objects | KNP, AMWPP | |
MF4 | Removal of foreign objects, pre-filtering |
KNP, AMWPP | ||
TH2 | Separation of oil | TH oil-water separator | ||
Recycling of press oil | MF5 | Removal of foreign objects from press oil | AMWSC | |
MA | Removal of moisture and foreign objects from press oil | MA oil purifier | ||
Generation of rinse water | MF6 | Removal of foreign objects from rinse water | KNA, KYS |
*Click here for more examples of cleaning-related installation flows.